                                                        CPC112592
                                                                 
                                                          701.DOC
                  The Complete TurboModem Plus
                     Using Lap Link Pro 4.0
                                
                                
This document is provided as "For your information" and as is.
Neither The Complete PC nor any of it's employees assume any
responsibility for consequences resulting from the use of the
following information nor can the Complete PC technical support
provide help with this document.  The user of said information
does so at his or her own risk.

This document discusses the use of Lap Link Pro 4.0 on the
Complete TurboModem Plus.  The following information describes
configuration in Lap Link Pro necessary for the software to
function with the Complete TurboModem Plus.  Please note the
following information is presented with the assumption that you
are using a mouse.  If you are not using a mouse, please refer to
the Lap Link Pro manual concerning equivalent keyboard commands.

Setting up Lap Link Pro
To configure Lap Link Pro for use with the Complete TurboModem
Plus.  First you must execute the Lap Link program.  Then choose
Options and select Port/Modem Setup.  Choose the modem serial
port used by the Complete TurboModem Plus.  You will be presented
with a modem list.  The Complete TurboModem Plus will not be
listed in the selection menu so you must choose Hayes Ultra 9600.

The settings Tone Dial and Auto Answer will have to be checked if
they aren't already.  Then goto Setup Port... and make sure
Enable Port, Use Modem, and Forced Standard (3-Wire) Mode are all
checked.  Set the Baud Rate setting to the modem's maximum speed
of 57,600.

Click OK and then Done to save the changes .  The TurboModem Plus
is now configured for Lap Link Pro.

Using Lap Link Pro
Once the initialization string is modified, please consult your
Lap Link manual on calling and logging onto another Lap Link
machine.  Since Lap Link Pro does not operate in resident memory,
it must be on screen at all times for it to function.  If Lap
Link Pro is not operating in the foreground the software will not
work.  If you have questions concerning the use of Lap Link Pro
please contact Traveling Software.

Other Considerations
If problems develop please check the following for possible
problems.  Make sure the Com port setting in Lap Link Pro matches
the setting on the TurboModem Plus.  If you receive a failure in
connecting be sure to check the modem with a communications
package to ensure the modem functions properly.  Be sure to check
to see if the modem initialization string matches the above
configuration.
